Dwyer 2-5000-3KPA-NPT Differential Pressure Gage

Dwyer 2-5000-3KPA-NPT Differential Pressure Gage

2-5000-3KPA-NPT | DIFFERENTIAL PRESSURE GAGE | RANGE 0-3 KPA | 1/8″ MALE NPT CONNECTION. | DWYER

Details for 2-5000-3KPA-NPT

See catalog product page for full listingDifferential pressure gage | range 0-3 kPa | 1/8″ male NPT connection.

Series 2-5000 Minihelic® II Differential Pressure Gage

Combining High Accuracy, Compactness, Dependability, and Low Cost

Combining clean design, small size and low cost with enough accuracy for all but the most demanding applications our Series 2-5000 Minihelic® II Differential PressureGage offers the latest in design features for a dial type differential pressure gage. It is our most compact gage but is easy to read and can safely operate at total pressures up to 30 psig.

NIST CALIBRATION available in Product Configurator.

DID YOU KNOW that you can add YOUR logo to our Minihelic® Pressure Gage, call customer service for details.

Product Applications

  • Room Positive Pressure Sensing
  • Local Indication on Filter Status
  • Removable lens and rear-housing provides easy, cost-effective servicing
  • Accuracy and value provides an excellent solution for OEM and user applications
  • Durable housing materials make it well-suited for rough environments and total high pressure

Specifications

Series-2-5000 Minihelic® II Differential Pressure Gage
Category/Type-Pressure
Type-Differential Pressure
Series-2-5000 Minihelic® II Differential Pressure Gage
Service-Air and compatible gases.
Wetted Materials-Consult factory.
Housing-Glass filled nylon; polycarbonate lens.
Accuracy-±5% of FS at 70°F (21.1°C).
Pressure Limits-30 psig (2.067 bar) continuous to either pressure connection.
Temperature Limits-20 to 120°F (-6.67 to 48.9°C).
Mounting Orientation-Diaphragm in vertical position. Consult factory for other position orientations.
Process Connections-Barbed; for 3/16″ ID tubing (standard); 1/8″ male NPT (optional).
Weight-6 oz (170.1g).
Agency Approvals-Meets the technical requirements of EU Directive 2011/65/EU (RoHS II).
CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE NON-CORROSIVE GASES.